In this report, a case of enterocutaneous fistula was presented which was developed due to the compression of folding of the adhesion barrier mesh placed intraperitoneally. After removal of the mesh, fistula was excised and intestine was sutured primarily. The skin was sutured primarily without fascial closure. Eventration was developed as a result of skin necrosis. After surface of the intestine was covered by the granulation tissue, it was closed with autologous skin graft. The case was discussed about possible risk factors and treatment options in the light of pertinent literature.
Enterocutaneous fistula hernia small intestine intraperitoneal mesh
Bu yazıda, intraperitoneal yerleştirilen adezyon bariyerli mesh katlantılarının ince barsağa basısı sonucu enterokutan fistül gelişen bir olgu sunulmaktadır. Hastadaki mesh çıkarıldıktan sonra fistül eksize edildi ve barsak primer sütürle kapatıldı. Fasya defektine dokunulmaksızın cilt dikildi. Cilt nekrozu sonucu evantrasyon gelişti. Barsakların üzeri granülasyon dokusu ile kaplandıktan sonra cilt greftiyle kapatıldı. Olgumuz olası risk faktörleri ve tedavi seçenekleri açısından literatür eşliğinde tartışıldı.