The assessment of anterior segment parameters using the Sirius topography in adults with anisohypermetropic amblyopia
Abstract
Aim: To evaluate anterior segment parameters in the eyes of adults with anisohypermetropic amblyopia using the Sirius topography device.
Materials and Methods: Forty-eight patients with anisohypermetropic amblyopia were prospectively evaluated along with a control group of 45 healthy patients. All patients were examined with the Sirius topography system under cycloplegic and non-cycloplegic conditions. The anterior and posterior mean keratometry values, central corneal thickness (CCT), anterior chamber depth (ACD), corneal volume (CV), and anterior chamber volume (ACV) measurements were compared among groups.
Results: No significant difference was found in the anterior and posterior mean keratometry values, CCT, ACD, CV, and ACV measurements between amblyopic, fellow, and control eyes under cycloplegic and non-cycloplegic conditions (p>0.05).
Conclusion: This study shows that the anterior segment parameters measured by the Sirius topography device among amblyopic, fellow, and control eyes do not differ under both cycloplegic and non-cycloplegic conditions.
Keywords
Kaynakça
- Noorden GK. Mechanisms of amblyopia. Adv Ophthalmol 1977;34(2):93-115.
- Cole RB. The problem of unilateral amblyopia: a preliminary study of 10,000 National Health patients. Br Med J 1959;1(5116): 202-6.
- Attebo K, Mitchell P, Cumming R, Smith W, Jolly N, Sparkes R. Prevalence and causes of amblyopia in an adult population. Ophthalmology 1998;105(1):154-9.
- Wang Y, Liang YB, Sun LP, et al. Prevalence and causes of amblyopia in a rural adult population of Chinese the Handan Eye Study. Ophthalmology 2011;118(2):279-83.
- Rabin J, Van Sluyters RC, Malach R. Emmetropization: A vision-dependent phenomenon. Invest Ophthalmol Vis Sci 1981;20(4):561-4.
- Pineles SL, Demer JL. Bilateral abnormalities of optic nerve size and eye shape in unilateral amblyopia. Am J Ophthalmol 2009;148(4):551-7.
- Barnes GR, Li X, Thompson B, Singh KD, Dumoulin SO, Hess RF. Decreased gray matter concentration in the lateral geniculate nuclei in human amblyopes. Invest Ophthalmol Vis Sci 2010;51(3):1432-8.
- Soyugelen G, Onursever N, Bostancı- Ceran B, Can İ. Strabismik ve anizometropik ambliyop olgularda makula kalınlığı ve retina sinir lifi tabakasının optik koherens tomografi ile değerlendirilmesi. Turk J Ophthalmol 2011;41(5):318-24.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Sağlık Kurumları Yönetimi
Bölüm
Araştırma Makalesi
Yazarlar
Sevil Karaman Erdur
0000-0001-9829-7268
Türkiye
Funda Dikkaya
*
0000-0003-2312-2521
Türkiye
Göktuğ Demirci
0000-0002-5079-4713
Türkiye
Mustafa Özsütçü
0000-0001-8954-5055
Türkiye
Rukiye Aydın
0000-0003-0668-3749
Türkiye
Mustafa Eliaçık
0000-0002-2563-2149
Türkiye
Mehmet Selim Kocabora
0000-0001-5335-3860
Türkiye
Yayımlanma Tarihi
14 Eylül 2018
Gönderilme Tarihi
30 Mayıs 2017
Kabul Tarihi
24 Ağustos 2017
Yayımlandığı Sayı
Yıl 2018 Cilt: 57 Sayı: 3