EN
TR
Comparison of computerized planning and TLD dosimetry measurements in gynecological endocavitary brachytherapy applications
Abstract
Aim: Dosimetric evaluation of rectum and bladder doses in endocavitary brachytherapy treatment of patients with operated/inoperable cervix and endometrium cancer.
Materials and Methods: A rectal probe with thermoluminescence dosimetry (TLD) was inserted to measure doses in the rectum in endocavitary brachytherapy treatments of 10 inoperable, 12 operated patients with cervical and endometrial cancer. A foley catheter (balloon) in the neck of the bladder and a chain in its base was placed to determine the bladder doses.
Applicator points, vagina, bladder, and rectum points were determined on the radiographs of the patients taken in the simulator, and dose distributions were calculated in the brachytherapy treatment planning system. Doses calculated at 4 points in the rectum and measured by TLD were compared as a percentage difference. The dose at the bladder neck was statistically compared with the highest dose at its base.
Results: The differences between the two techniques in operated and inoperable patients for the rectum; respectively, maximum 17.68% and 17.96%, minimum 0.38% and 0.20%, mean R1:5.62%, R2:4.22%, R3:5.96%, R4:7,58% and R1:6.73%, R2:4.36%, R3:4.34%, R4: 7.53% were determined. While the difference between the bladder neck and the maximum dose point at its base was significant in operated patients (p=0.0037), it was insignificant in inoperable patients (p=0.3863).
Conclusion: The difference between the calculated and measured doses in the rectum is not clinically significant. Doses for rectal complications should be determined at multiple points. The dose determined at the bladder neck is not sufficient for bladder complications, the doses should also be determined at the base of the bladder.
Keywords
Supporting Institution
---
Project Number
---
Thanks
Sayın Editör,
Bu araştırma makalesini değerlendirdiğiniz için teşekkür ederiz.
References
- Delclos L, Flectcher GH. Gynecolog Cancer. In:Levitt SH, Tapley N (eds). Technological Basis of Radiation Therapy: Practical Clinical Applications. 1st ed. Philadelphia: Lea & Febiga; 1992:263-88.
- Dobbs J,Barret A, Ash D. Cervix Uteri and Corpus Uteri. In: Dobbs J, Barrett A (eds). Practical Radiotherapy Planning. 2nd ed. Melbourne: A division of Holder & Stoughon;1992:241-56.
- Nag S, Scruggs GR. Clinical Aspects and Applications of High–Dose-Rate Brachytherapy. In: Halperin EC, Wazer DE, Perez CA, Brady LW (eds). Principles and Practice of Radiation Oncology. 6th ed. Philadelphia: Lippincott Williams &Wilkins; 2013:507-24.
- Kapp KS, Stuecklschweiger GF, Kapp DS, Hackl AG. Dosimetry of intracavitary placement for uterine and cervical carcinoma: Results of orthogonal film, TLD, and CT-assisted techniques. Radiother Oncol 1992;24(3):137-46.
- Lahtinen T, Tenhunen M, Väyrynen M. ICRU reference points and maximum doses of rectum and bladder in intracavitary radiotherapy. Radiother Oncol 1993;28(2):174-6.
- Montana GS, Fowler WC. Carcinoma of the cervix: Analysis of bladder and rectal radiation dose and complications. Int J Radiat Oncol Biol Phys 1989;16(1):95-100.
- Kapp KS, Stuecklschweiger GF, Kapp DS, Poschauko J, Pickel H, Hackl A. Carcinoma of the cervix: Analysis of complications after primary external beam radiation and IR-192 HDR brachytherapy. Radiother Oncol.1997;42(2):143-53.
- Terhima T, Chatani M, Hata K, Inoue T. High-Dose Rate intracavitary therapy for carcinoma of the uterine cervix: II. Risk factors for rectal complication. Int J Radiat Oncol Biol Phys 1988;14(2):281-6.
Details
Primary Language
Turkish
Subjects
Radiation Therapy , Health Physics
Journal Section
Research Article
Publication Date
June 10, 2024
Submission Date
June 15, 2023
Acceptance Date
December 12, 2023
Published in Issue
Year 1970 Volume: 63 Number: 2