Aneurysm of membranous septum as a long-term complication of mechanical aortic valve replacement

Volume: 51 Number: 4 December 1, 2012
  • Talay S
  • Kaygın M A
  • Dağ Ö
  • Erkut B
EN TR

Aneurysm of membranous septum as a long-term complication of mechanical aortic valve replacement

Abstract

We report a case of an unusual morphological complication of a mechanical aortic valve replacement which was observed as an aneurysm formation from the interventricular membranous septum during the first postoperative year. The aneurysm resulted in a functional impairment of the mechanical prosthesis with elevated pressure gradients and valve leak. However, due to the severe neurological status of the patient's emergent administration, an aneurysmectomy and/or renewal of aortic valve prosthesis was not possible. We hereby present the clinical and echocardiographical evaluation of the case.

Keywords

Details

Primary Language

Turkish

Subjects

-

Journal Section

-

Authors

Talay S

Kaygın M A

Dağ Ö

Erkut B

Publication Date

December 1, 2012

Submission Date

December 1, 2012

Acceptance Date

-

Published in Issue

Year 2012 Volume: 51 Number: 4

Vancouver
1.Talay S, Kaygın M A, Dağ Ö, Erkut B. Mekanik aort kapak replasmanının uzun dönem bir komplikasyonu olarak membranöz septum anevrizması. EJM [Internet]. 2012 Dec. 1;51(4):267-8. Available from: https://izlik.org/JA74CT49JY