Comparison of the results of ultrasonography-guided percutaneous liver mass biopsy performed with 18 and 20 gauge needles
Abstract
Aim: To evaluate the role of using 18 Gauge (G) and 20G sharp needles in ultrasonography (US)-guided percutaneous liver mass biopsy regarding diagnostic success and efficacy is aimed.
Materials and Methods: Sixty patients who underwent US-guided liver mass biopsy using 18G and 20G cutting needles were included in the study. Definite diagnosis was established based on results of histopathological examinations of the biopsied lesions, follow-up clinical and imaging findings and for performed patients the results of repeated biopsy. In addition, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for 18G and 20G needles.
Results: Among 60 liver masses, definite diagnosis was malignant in 54 (90%) masses and benign in 6 (10%) masses. Sensitivity, specificity, PPV, NPV, and diagnostic accuracy were 90.7%, 100.0%, 100.0%, 75.0%, and 91.6%, respectively, for the liver mass biopsies performed with 18G needles. These values were 87.0%, 100.0%, 100.0%, 66.7%, and 88.3%, respectively, for the liver mass biopsies performed with 20G needles. No significant difference was determined between the results found for the use of 18G needle and 20G needle in US-guided cutting needle biopsy performed in hepatic masses (p=0.540)
Conclusion: The present study demonstrated that 18G and 20G sharp needles had similar diagnostic success and efficacy in US-guided percutaneous biopsy of liver mass lesions. Owing to its fine calibration, 20G sharp needle can be preferred in high-risk patient groups, particularly in those with bleeding disorder.
Keywords
Kaynakça
- Strassburg CP, Manns MP. Approaches to liver biopsy techniques--revisited. Semin Liver Dis 2006;26(4):318-27.
- Fulcher AS, Sterling RK. Hepatic neoplasms: computed tomography and magnetic resonance features. J Clin Gastroenterol 2002;34(4):463-71.
- Bonder A, Afdhal N. Evaluation of liver lesions. Clin Liver Dis 2012;16(2):271-83.
- Rockey DC, Caldwell SH, Goodman ZD, Nelson RC, Smith AD. Liver Biopsy. Hepatology 2009;49(3):1017-44.
- Gupta S. New techniques in image-guided percutaneous biopsy. Cardiovasc Intervent Radiol 2004;27(2):91-104.
- Al Knawy B, Shiffman M. Percutaneous liver biopsy in clinical practice. Liver Int 2007;27(9):1166-73.
- Zornoza J, Wallace S, Ordonez N, Lukeman J. Fine-needle aspiration biopsy of the liver. AJR Am J Roentgenol 1980;134(2):331-4.
- Hopper KD, Abendroth CS, Sturtz KW, Matthews YL, Shirk SJ, Stevens LA. Blinded comparison of biopsy needles and automated devices in vitro: 1. Biopsy of diffuse hepatic disease. AJR Am J Roentgenol 1993;161(6):1293-7.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Sağlık Kurumları Yönetimi
Bölüm
Araştırma Makalesi
Yazarlar
Cenk Eraslan
*
0000-0002-5762-6149
Türkiye
Ömer Faruk Kutsi Köseoğlu
0000-0001-7615-4266
Türkiye
Nezih Meydan
0000-0003-4100-5804
Türkiye
Nil Çulhacı
0000-0001-7181-4675
Türkiye
Aylin Oral
0000-0001-8014-4327
Türkiye
Yayımlanma Tarihi
14 Mart 2019
Gönderilme Tarihi
18 Ocak 2018
Kabul Tarihi
2 Şubat 2018
Yayımlandığı Sayı
Yıl 2019 Cilt: 58 Sayı: 1
Cited By
Investigation of the Penetration Force of Disposable Sterile Needles through Biomedical Textile Surfaces
Engineering, Technology & Applied Science Research
https://doi.org/10.48084/etasr.5459