We report a case of an unusual morphological complication of a mechanical aortic valve replacement which was observed as an aneurysm formation from the interventricular membranous septum during the first postoperative year. The aneurysm resulted in a functional impairment of the mechanical prosthesis with elevated pressure gradients and valve leak. However, due to the severe neurological status of the patient's emergent administration, an aneurysmectomy and/or renewal of aortic valve prosthesis was not possible. We hereby present the clinical and echocardiographical evaluation of the case.
Biz bu yazıda mekanik aort kapak replasmanı yapılan bir hastada postoperatif birinci yılında gelişen interventriküler membranöz septumun anevrizması olgusunu sunduk. Mevcut anevrizma mekanik kapakta fonksiyonel bir bozulmaya neden olarak aort kapağa ait yüksek bir gradiente ve kapakta kaçağa sebep olmuştur. Hastadaki nörolojik durum bozukluğu nedeniyle cerrahi olarak anevrizmektomi ya da yeni kapak protez uygulamasına gidilmemiştir. Bu olguda hastaya ait klinik ve ekokardiyografik değerlendirme bulgularından bahsetmekteyiz.
Other ID | JA66CD33NU |
---|---|
Journal Section | Case Reports |
Authors | |
Publication Date | December 1, 2012 |
Submission Date | December 1, 2012 |
Published in Issue | Year 2012Volume: 51 Issue: 4 |